Compatibility Instructions for all ecowitt network consolesUpdated 2 months ago
console - sensor - maximum number table
upload only: upload to your personal account (dashboard) at ecowitt.net resp. in the Ecowit app/WS View Plus app (Ecowitt dashboard)
Beware that the whole number of WFC01/AC1100 devices is limited to 16. Any combination between 0/16 and 16/0 is possible.
The GW1000 and the WH2650 are no longer contained in the above matrix.
However, they can be considered the same as a HP25x0/HP350x console regarding the number and type of possible sensors which can be connected to them. In fact, on firmware 1.7.7, they both can register all Ecowitt sensors except the IoT sensors (WFC01, AC1100).
They can even display synoptically a traditional and a piezo rain gauge in the WS View Plus app while until now (February 2024) the HP25x0/HP350x consoles can only display on their screen one of the rain gauges. A cycling is not (yet ?)implemented.
The new WS85 Rain & Wind sensor can not be registered by a GW1000/WH2650.
Their firmware will no longer be updated to support new sensors.